Bardan, Gérald and Plouraboué, Franck and Zagzoule, Mokhtar and Balédent, Olivier Pressure drop reconstruction in the aqueduct of sylvius from MRI acquisitions. (2012) Computer Methods in Biomechanics and Biomedical Engineering, 15 (Supp 1). 79-80. ISSN 1025-5842

[img]
Preview
(Document in English)

PDF (Author's version) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
104kB

Official URL: http://dx.doi.org/10.1080/10255842.2012.713735

Abstract

From measurement of the oscillating flux of the cerebrospinal liquid (CSL) in the aqueduct of Sylvius, we elaborate a patient-based methodology for pressure evaluation. Highresolution anatomical MRI first permits a precise threedimensional anatomical digitalyzed reconstruction of the Sylvius’s aqueduct shape. Cine phase-contrast MRI is now an invaluable tool for pathologies investigations (Tain and Alperin 2009) for the evaluation of blood flow in then brain vessels as well as inside the CSL flow inside the brain cavities. It permits the evaluation of the CSL pulsatile flux inside the aqueduct.

Item Type:Article
HAL Id:hal-04498388
Audience (journal):International peer-reviewed journal
Uncontrolled Keywords:
Institution:Other partners > Centre hospitalier universitaire d'Amiens - CHU Amiens-Picardie (FRANCE)
French research institutions > Centre National de la Recherche Scientifique - CNRS (FRANCE)
Université de Toulouse > Institut National Polytechnique de Toulouse - Toulouse INP (FRANCE)
Université de Toulouse > Université Toulouse III - Paul Sabatier - UT3 (FRANCE)
Laboratory name:
Statistics:download
Deposited On:30 Nov 2012 14:13

Repository Staff Only: item control page