OATAO - Open Archive Toulouse Archive Ouverte Open Access Week

Coonrad-Morrey total elbow arthroplasty for patients with rheumatoid arthritis: 54 prostheses reviewed at 7 years' average follow-up (maximum, 16 years)

Pham, Thuy Trang and Delclaux, Stéphanie and Huguet, Sandrine and Wargny, Matthieu and Bonnevialle, Nicolas and Mansat, Pierre Coonrad-Morrey total elbow arthroplasty for patients with rheumatoid arthritis: 54 prostheses reviewed at 7 years' average follow-up (maximum, 16 years). (2018) Journal of Shoulder and Elbow Surgery, 27 (3). 398-403. ISSN 1058-2746

[img]
Preview
(Document in English)

PDF (Author's version) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
780kB

Official URL: https://doi.org/10.1016/j.jse.2017.11.007

Abstract

BACKGROUND: Total elbow arthroplasty is a therapeutic option for severe rheumatoid arthritis. We hypothesized that the semiconstrained characteristics of the Coonrad-Morrey prosthesis do not compromise the survival rate of the implant in a rheumatoid elbow. METHODS: Between 1997 and 2012, there were 54 Coonrad-Morrey total elbow prostheses performed for rheumatoid arthritis in 46 patients. Minimum follow-up was 2 years. There were 35 women and 11 men with a mean age of 60 years (29-83 years). According to the Mayo classification for rheumatoid elbow, there were 30 type IIIA, 21 type IIIB, and 3 type IV. The surgical procedure was the same for all patients. Survivorship was assessed with use of the Kaplan-Meier method, with revision surgery as the end point. RESULTS: The survival rate was 97% (95% confidence interval, 83.6-99.6) at 5 years and 85% (95% confidence interval, 68.3-93.7) at 10 years. At an average of 7 years of follow-up (2-16 years), the mean Mayo Elbow Performance Score was 91 points (55-100 points), and the shortened version of the Disabilities of the Arm, Shoulder, and Hand score was 34 points (0-75 points). There was a significant improvement in Mayo Elbow Performance Score and in all range of motion at latest follow-up in comparison to preoperative values (P < .0001). Radiolucencies were observed in 6 cases around the humeral component and in 6 cases around the ulnar component. Bushing wear was observed in 16 cases (29%). There were 14 complications (26%). Revisions were performed in 6 of them (11%). CONCLUSION: The Coonrad-Morrey prosthesis provides satisfactory results with follow-up. The rate of complications remains high even if the rate of implant revision stayed low.

Item Type:Article
HAL Id:hal-01833927
Audience (journal):International peer-reviewed journal
Uncontrolled Keywords:
Institution:French research institutions > Centre National de la Recherche Scientifique - CNRS (FRANCE)
French research institutions > Institut National de la Santé et de la Recherche Médicale - INSERM (FRANCE)
Other partners > Université de Nantes (FRANCE)
Other partners > Centre Hospitalier Universitaire de Nancy - CHU Nancy (FRANCE)
Other partners > Centre Hospitalier Universitaire de Toulouse - CHU Toulouse (FRANCE)
Laboratory name:
Statistics:download
Deposited On:13 Mar 2019 09:17

Repository Staff Only: item control page